The motor speed has exceeded 115% of its rated speed. When the spindle axis was in position control mode, positional deviations were accumulated excessively (SFR and SRV were turned off during spindle synchronization.)
Check for a sequence error. (For example, check whether spindle synchronization was specified when the spindle could not be turned.)
Spindle Amplifier indication 07
NOTE*1 Note that the meanings of the Spindle Amplifier indications differ depending onwhich LED, the red or yellow LED, is on. When the red LED is on, the SpindleAmplifier indicates a 2-digit alarm number. When the yellow LED is on, theSpindle Amplifier indicates an error number that designates a sequence problem(for example, when a rotation command is entered with the emergency stopstate not released).See “Error Codes (Serial Spindle).”*2 For serial spindle alarms with a number not listed, refer to the followingdocuments depending on the spindle motor to which a connection is actuallymade.