SP9007 SSPA:07 Over Speed

The motor speed has exceeded 115% of its rated speed. When the spindle axis was in position control mode, positional deviations were accumulated excessively (SFR and SRV were turned off during spindle synchronization.)

Check for a sequence error. (For example, check whether spindle synchronization was specified when the spindle could not be turned.)

Spindle Amplifier indication 07

NOTE
*1 Note that the meanings of the Spindle Amplifier indications differ depending on
which LED, the red or yellow LED, is on. When the red LED is on, the Spindle
Amplifier indicates a 2-digit alarm number. When the yellow LED is on, the
Spindle Amplifier indicates an error number that designates a sequence problem
(for example, when a rotation command is entered with the emergency stop
state not released).
See “Error Codes (Serial Spindle).”
*2 For serial spindle alarms with a number not listed, refer to the following
documents depending on the spindle motor to which a connection is actually
made.