FANUC ALARM
Fastest way to solve problems
A Spindle Amplifier (SP) overload current was detected.
1 Review operation conditions (acceleration/deceleration and cutting) to reduce the load.2 Check and correct the parameters.
Spindle Amplifier indication 22
NOTE*1 Note that the meanings of the Spindle Amplifier indications differ depending onwhich LED, the red or yellow LED, is on. When the red LED is on, the SpindleAmplifier indicates a 2-digit alarm number. When the yellow LED is on, theSpindle Amplifier indicates an error number that designates a sequence problem(for example, when a rotation command is entered with the emergency stopstate not released).See “Error Codes (Serial Spindle).”*2 For serial spindle alarms with a number not listed, refer to the followingdocuments depending on the spindle motor to which a connection is actuallymade.
Your email address will not be published. Required fields are marked *
Comment *
Name *
Email *
Website
Save my name, email, and website in this browser for the next time I comment.