FANUC ALARM
Fastest way to solve problems
The motor cannot rotate at a specified speed. (A level not exceeding the SST level for the rotation command has existed continuously.)
1 Check and correct the load status.2 Replace the motor sensor cable (connector JYA2).
Amplifier indication 31
NOTE*1 Note that the meanings of the Spindle Amplifier indications differ depending onwhich LED, the red or yellow LED, is on. When the red LED is on, the SpindleAmplifier indicates a 2-digit alarm number. When the yellow LED is on, theSpindle Amplifier indicates an error number that designates a sequence problem(for example, when a rotation command is entered with the emergency stopstate not released).See “Error Codes (Serial Spindle).”*2 For serial spindle alarms with a number not listed, refer to the followingdocuments depending on the spindle motor to which a connection is actuallymade.