Charging of direct current power supply voltage in the power circuit section is insufficient when the magnetic contractor is turned on (such as open phase and defective charging resistor). (Power Supply alarm indication: 05)
1 Check and correct the power supply voltage.2 Replace the Power Supply (PS).
Amplifier indication 33
NOTE*1 Note that the meanings of the Spindle Amplifier indications differ depending onwhich LED, the red or yellow LED, is on. When the red LED is on, the SpindleAmplifier indicates a 2-digit alarm number. When the yellow LED is on, theSpindle Amplifier indicates an error number that designates a sequence problem(for example, when a rotation command is entered with the emergency stopstate not released).See “Error Codes (Serial Spindle).”*2 For serial spindle alarms with a number not listed, refer to the followingdocuments depending on the spindle motor to which a connection is actuallymade.